{"product_id":"ciuzinys-nuo-pragulu-su-vartymo-funkcija-turnmate","title":"TurnMate Anti-Reflux Mattress with Rotation Function","description":"\u003cstrong\u003eTurnMate alternating pressure mattress with turning function \u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe alternating pressure mattress set for pressure ulcer prevention consists of an alternating pressure mattress and a compressor (pump) with a remote control. The alternating pressure system is cyclically and alternately inflated by the compressor (zones A and B). The mattress has a function allowing the patient to be turned to the right\/left, as well as raising the head and leg sections. The mattress is made of thermoplastic polyurethane (TPU) – a flexible and durable material that combines the properties of rubber and plastic. The mattress has a CPR function (rapid air release from the chambers when resuscitation is required). The compressor has three operating modes: alternating pressure mode, sleep mode, and massage mode.\u003cbr\u003e\u003cbr\u003eThe alternating pressure mattress for pressure ulcer prevention belongs to the auxiliary equipment intended for persons who are at an increased risk of developing pressure ulcers. It is used for people who lie down for long periods, persons with impaired peripheral circulation, as well as persons who show signs of subcutaneous or open skin damage caused by prolonged pressure. The mattress is used both for the prevention and treatment of pressure ulcers up to stage III (according to NPUAP\/EPUAP). The principle of operation is based on the cyclic change of pressure at the support points of the lying person, thereby reducing pressure on the body parts that are at the highest risk of developing pressure ulcers. In this way, the mattress ensures better blood circulation to the body parts that are in the longest contact with the surface. It should be noted that the principle of operation of the mattress cannot eliminate all causes of pressure ulcers, but it can significantly limit their development.\u003cbr\u003e\u003cbr\u003eThe contraindications for using the alternating pressure mattress are determined by the treating physician during subjective and objective examinations. It is generally recognized that the mattress cannot be used in cases where the alternating change of pressure at the support points causes the patient pain or worsens the course of their illness.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cul\u003e \t\u003cli\u003eThree operating modes: turning\/massage, alternating, sleep\u003c\/li\u003e \t\u003cli\u003eTurning mode (massage). Four options: low, medium, high, and sleep, maximum turning angle is 30-5°, the mattress can turn from one side to the other to improve blood circulation.\u003c\/li\u003e \t\u003cli\u003eAlternating mode. This is the effect of high contact pressure areas by distributing the body mass over a larger surface area in a \"submersion\" manner. After 20 minutes in static mode, the pump returns to alternating mode.\u003c\/li\u003e \t\u003cli\u003eSleep mode. The air chambers are filled unevenly, without alternation, to reduce the impact on sleep quality.\u003c\/li\u003e \t\u003cli\u003eCycle time selection 10\/15\/20 min.\u003c\/li\u003e \t\u003cli\u003eAdjustable pressure according to the patient's weight (40–200 kg). Automatically adapts to the patient's weight; with head elevation, leg elevation, turning to the left and right functions\u003c\/li\u003e \t\u003cli\u003e18-channel design, made of TPU film \/ nylon with TPU coating\u003c\/li\u003e \t\u003cli\u003eWith CPR, so that air can be quickly released during patient resuscitation\u003c\/li\u003e \t\u003cli\u003eRemote control\u003c\/li\u003e \t\u003cli\u003eAB alternative for pressure ulcer prevention\u003c\/li\u003e \t\u003cli\u003eVisual and audible alarm signals for patient safety.\u003c\/li\u003e \t\u003cli\u003eReinforced, stitched, water-resistant and steam-permeable elastic PU cover with a zipper around\u003c\/li\u003e \t\u003cli\u003eExternally, easily replaceable compressor filters in static mode.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e\u003cul\u003e \t\u003cli\u003eThe set consists of: compressor (alternating pressure pump), tubular mattress with air hoses, cover, compressor fuses (2 pcs.), spare mattress chamber (1 pc.), remote control.\u003c\/li\u003e \t\u003cli\u003e\u003cstrong\u003eMaximum load: 200kg\u003c\/strong\u003e\u003c\/li\u003e \t\u003cli\u003e\u003cstrong\u003eDimensions: 200*90*11.5 cm\u003c\/strong\u003e\u003c\/li\u003e \t\u003cli\u003eCompressor: 30 × 14 × 27 cm\u003c\/li\u003e \t\u003cli\u003eMattress weight: 9.50 kg\u003c\/li\u003e \t\u003cli\u003eCompressor weight: 2.80 kg\u003c\/li\u003e \t\u003cli\u003eCycle time: 10 \/ 15 \/ 20 minutes\u003c\/li\u003e \t\u003cli\u003ePressure range: 25–55 mmHg\u003c\/li\u003e \t\u003cli\u003eAirflow: ＞300 L\/h\u003c\/li\u003e \t\u003cli\u003ePower supply: 220 V ±10 % 50 Hz\u003c\/li\u003e \t\u003cli\u003ePower consumption: ≤20 W\u003c\/li\u003e \t\u003cli\u003eNoise level: 37 dB\u003c\/li\u003e\n\n\n\u003c\/ul\u003eDelivery time up to 15 days.\u003cbr\u003e\u003cbr\u003ehttps:\/\/youtu.be\/4QSXOVMgBlc","brand":"slaugyk","offers":[{"title":"Default Title","offer_id":53939091374427,"sku":"turnmate","price":1450.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1031\/5893\/9995\/files\/turnmate-ciuzinys-slaugyk.lt.png?v=1788195769","url":"https:\/\/slaugyk.lt\/en\/products\/ciuzinys-nuo-pragulu-su-vartymo-funkcija-turnmate","provider":"Slaugyk.lt","version":"1.0","type":"link"}